Operating Temperature Data:

-40 C to +85 C ( AST-14-S )

-55 C to +85 C ( AST-14-L )

Electrical Ratings

Supply
Voltage Range
Frequency
Current
Range ( avg)
Inrush
Current (max)
T Code
@ 40 C
T code
@ 85 C
90 to 130 VAC
50/60Hz
.118 A to .090 A
.250 A
T3C
T3
220 to 250 VAC
50/60Hz
.072 A to .055 A
.220 A
T3A
T2C
10 to 30 VDC
-
.8 A to .4 A
1.30 A
T3A
T2C
50 to 60 VDC
-
.360 A to .300 A
. 820 A
T2D
T2B
90 to 130 VDC
-
.175 A to .090 A
.250 A
T3C
T3
220 to 250 VDC
-
.070 A to .055 A
.220 A
T3A
T2C
15 to 30 VDC
-
.8 A to .4 A
1.30 A
T3A
T2C

Net Weight : 4.5 lbs

Ordering Information

Model No Input Voltage
AST-14-*-90-130-AC 90 -130 VAC
AST-14-*-220-250-AC 220-250 VAC
AST-14-*-10-30-DC 10 - 30 VDC
AST-14-*-90-130-DC 90 - 130 VDC
AST-14*--220-250-DC 220-250 VDC
AST-14-*-50-60-DC 50-60 VDC
AST-14-*-15-30-DC 15-30 VDC
NOTE * -S for standard temperature range and -L for low temperature range

Lens Colors
AM - Amber
BL - Blue
GR - Green
RE - Red
CL - Clear
PU - Purple

Ordering Example
AST-14-S-10-30-DC-RE
ULC Approved
AST-14-L-15-30-DC-CL-ULC

PENDANT MOUNT
HAZARDOUS AREA STROBE